PVC 3 CORE FLAT CABLES

Submersible Pump cables is a specialized product
to be used for submersible pumps in a deep well. The area of installation
is physically restrictive, and the environment is very hostile.
| 3 CORE FLAT CABLES
FOR SUBMERSIBLE PUMPS (1100 VOLTS)
|
| CONDUCTOR
|
PVC
INSULATION |
PVC
SHEATH |
Conductor
Resistance at 20°C (max) ohms/km |
CURRENT
Rating at 40°C
Amps. |
 |
Nominal
Area in
|
Nos.
& Dia.
of wire
|
Nominal
Thickness |
Nominal
Core Dia. |
Nominal
Thickness
|
Approx.
Overall
Dimensions |
| Sq.
mm. |
Nos.
/ mm |
mm |
mm |
mm |
Thickness
mm |
Width
mm |
| 1.50 |
22/0.30 |
0.80 |
3.25 |
1.15 |
6.00 |
12.80 |
12.10 |
14 |
| 2.50 |
36/0.30 |
0.90 |
3.84 |
1.15 |
6.40 |
14.60 |
7.41 |
18 |
| 4.00 |
56/0.30 |
1.00 |
4.50 |
1.15 |
7.40 |
16.80 |
4.95 |
26 |
| 6.00 |
85/0.30 |
1.00 |
5.30 |
1.15 |
7.90 |
18.70 |
3.30 |
31 |
| 10.00 |
140/0.30 |
1.00 |
6.50 |
1.40 |
9.90 |
23.70 |
1.91 |
42 |
| 16.00 |
226/0.30 |
1.00 |
8.00 |
1.40 |
11.40 |
28.00 |
1.21 |
57 |
| 25.00 |
354/0.30 |
1.20 |
10.10 |
2.00 |
14.70 |
35.50 |
0.780 |
72 |
| 35.00 |
495/0.30 |
1.20 |
11.30 |
2.00 |
16.20 |
39.50 |
0.554 |
90 |
| 50.00 |
703/0.30 |
1.40 |
13.60 |
2.20 |
18.30 |
45.50 |
0.386 |
115 |
| 70.00 |
440/0.45 |
1.40 |
15.30 |
2.20 |
20.00 |
51.00 |
0.272 |
143 |
| 95.00 |
475/0.50 |
1.60 |
18.00 |
2.40 |
23.50 |
60.00 |
0.206 |
165 |
Note
- The number of wires is approximate and wire
diameter is nominal; they shall be such as to satisfy the requirements
of conductor resistance as per Class 5 of IEC 60228 / DIN VDE
0295 / IS 8130 / BS 6360
- In view of continuous improvements
in our design and process, specifications given here in are subject
change without notice.
| 3 Core Flat Cables as per IS
694 : 1990 with ISI mark |
| CONDUCTOR |
PVC INSULATION |
PVC SHEATH |
Current Rating at 40°C
Amps. |
Nominal
Area
Sq. mm |
Nos. Dia
Of Wire
Nos./mm |
Nominal Thickness |
Nominal Thickness |
Approx
Overall Dimension |
| mm |
mm |
Thickness
mm |
Width
mm. |
| 1.5 |
22/0.30 |
0.6 |
0.9 |
5.20 |
11.30 |
14 |
| 2.5 |
36/0.30 |
0.7 |
1.0 |
6.20 |
13.30 |
18 |
| 4.0 |
56/0.30 |
0.8 |
1.0 |
7.00 |
15.60 |
26 |
| 6.0 |
84/0.30 |
0.8 |
1.1 |
7.40 |
17.70 |
31 |
Note
- The number of wires is approximate and wire
diameter is nominal.
- They shall be so as to satisfy the
requirements of conductor resistance as per
- Class 2 of IS 8130 : 1984 (For 1.5
& 2.5 sq. mm.) &
- Class 5 of IS 8130 : 1984 (For 4.0 &
6.0 sq. mm.)
PVC 4 CORE FLAT CABLES

| 4 CORE FLAT CABLES
FOR SUBMERSIBLE PUMPS (1100 VOLTS)
|
| CONDUCTOR
|
PVC
INSULATION |
PVC
SHEATH |
Conductor
Resistance at 20°C (max) ohms/km |
CURRENT
Rating at 40°C
Amps. |
 |
Nominal
Area in
|
Nos.
& Dia.
of wire
|
Nominal
Thickness |
Nominal
Core Dia. |
Nominal
Thickness
|
Approx.
Overall
Dimensions |
| Sq.
mm. |
Nos.
/ mm |
mm |
mm |
mm |
Thickness
mm |
Width
mm |
| 1.50 |
22/0.30 |
0.80 |
3.25 |
1.30 |
6.00 |
15.80 |
12.10 |
14 |
| 2.50 |
36/0.30 |
0.90 |
3.84 |
1.30 |
6.50 |
18.00 |
7.41 |
18 |
| 4.00 |
56/0.30 |
1.00 |
4.50 |
1.45 |
7.60 |
21.00 |
4.95 |
26 |
| 6.00 |
85/0.30 |
1.00 |
5.30 |
1.50 |
7.90 |
24.30 |
3.30 |
31 |
| 10.00 |
140/0.30 |
1.00 |
6.50 |
1.80 |
9.90 |
29.70 |
1.91 |
42 |
| 16.00 |
226/0.30 |
1.00 |
8.00 |
1.95 |
11.80 |
36.00 |
1.21 |
57 |
| 25.00 |
354/0.30 |
1.20 |
10.10 |
2.00 |
14.70 |
45.10 |
0.780 |
72 |
| 35.00 |
495/0.30 |
1.20 |
11.50 |
2.00 |
16.20 |
50.10 |
0.554 |
90 |
| 50.00 |
703/0.30 |
1.40 |
13.60 |
2.20 |
18.30 |
58.10 |
0.386 |
115 |
| 70.00 |
440/0.45 |
1.40 |
15.30 |
2.20 |
20.00 |
66.50 |
0.272 |
143 |
| 95.00 |
475/0.50 |
1.60 |
18.00 |
2.40 |
23.50 |
77.30 |
0.206 |
165 |
Note
- The number of wires is approximate and wire
diameter is nominal; they shall be such as to satisfy the requirements
of conductor resistance as per Class 5 of IEC 60228 / DIN VDE
0295 / IS 8130 / BS 6360
- In view of continuous improvements
in our design and process, specifications given here in are subject
change without notice.
PVC 3 CORE ROUND CABLES

| 3 CORE ROUND CABLES
FOR SUBMERSIBLE PUMPS (1100 VOLTS)
|
| CONDUCTOR
|
PVC
INSULATION |
TOTAL
THICKNESS OF DOUBLE PVC SHEATH |
Conductor
Resistance at 20°C (max) ohms/km |
CURRENT
Rating at 40°C
Amps. |
 |
Nominal
Area in
|
Nos.
& Dia.
of wire
|
Nominal
Thickness |
Nominal
Core Dia. |
Nominal
Thickness
|
Approx.
Overall
Dimensions |
| Sq.
mm. |
Nos.
/ mm |
mm |
mm |
mm |
mm |
| 1.50 |
22/0.30 |
0.80 |
3.25 |
1.50 |
10.00 |
12.10 |
14 |
| 2.50 |
36/0.30 |
0.90 |
3.84 |
1.50 |
11.00 |
7.41 |
18 |
| 4.00 |
56/0.30 |
1.00 |
4.50 |
1.60 |
13.00 |
4.95 |
26 |
| 6.00 |
85/0.30 |
1.00 |
5.30 |
1.60 |
14.60 |
3.30 |
31 |
| 10.00 |
140/0.30 |
1.00 |
6.50 |
2.00 |
18.00 |
1.91 |
42 |
| 16.00 |
226/0.30 |
1.00 |
8.00 |
2.00 |
21.20 |
1.21 |
57 |
| 25.00 |
354/0.30 |
1.20 |
10.10 |
2.15 |
26.00 |
0.780 |
72 |
| 35.00 |
495/0.30 |
1.20 |
11.30 |
2.15 |
28.30 |
0.554 |
90 |
| 50.00 |
703/0.30 |
1.40 |
13.60 |
2.25 |
33.50 |
0.386 |
115 |
| 70.00 |
440/0.45 |
1.40 |
15.30 |
2.45 |
37.80 |
0.272 |
143 |
| 95.00 |
475/0.50 |
1.60 |
18.00 |
2.40 |
43.50 |
0.206 |
165 |
Note
- The number of wires is approximate and wire
diameter is nominal; they shall be such as to satisfy the requirements
of conductor resistance as per Class 5 of IEC 60228 / DIN VDE
0295 / IS 8130 / BS 6360
- In view of continuous improvements
in our design and process, specifications given here in are subject
change without notice.
PVC 4 CORE ROUND CABLES

| 4 CORE ROUND CABLES
FOR SUBMERSIBLE PUMPS (1100 VOLTS)
|
| CONDUCTOR
|
PVC
INSULATION |
TOTAL
THICKNESS OF DOUBLE PVC SHEATH |
Conductor
Resistance at 20°C (max) ohms/km |
CURRENT
Rating at 40°C
Amps. |
 |
Nominal
Area in
|
Nos.
& Dia.
of wire
|
Nominal
Thickness |
Nominal
Core Dia. |
Nominal
Thickness
|
Approx.
Overall
Dimensions |
| Sq.
mm. |
Nos.
/ mm |
mm |
mm |
mm |
mm |
| 1.50 |
22/0.30 |
0.80 |
3.25 |
1.50 |
10.80 |
12.10 |
14 |
| 2.50 |
36/0.30 |
0.90 |
3.84 |
1.65 |
12.50 |
7.41 |
18 |
| 4.00 |
56/0.30 |
1.00 |
4.50 |
1.65 |
14.10 |
4.95 |
26 |
| 6.00 |
85/0.30 |
1.00 |
5.30 |
1.65 |
16.00 |
3.30 |
31 |
| 10.00 |
140/0.30 |
1.00 |
6.50 |
2.00 |
20.35 |
1.91 |
42 |
| 16.00 |
226/0.30 |
1.00 |
8.00 |
2.00 |
23.40 |
1.21 |
57 |
| 25.00 |
354/0.30 |
1.20 |
10.10 |
2.20 |
28.80 |
0.780 |
72 |
| 35.00 |
495/0.30 |
1.20 |
11.50 |
2.20 |
31.50 |
0.554 |
90 |
| 50.00 |
703/0.30 |
1.40 |
13.60 |
2.30 |
37.30 |
0.386 |
115 |
| 70.00 |
440/0.30 |
1.40 |
15.30 |
2.60 |
42.20 |
0.272 |
143 |
| 95.00 |
475/0.50 |
1.60 |
18.00 |
2.65 |
48.80 |
0.206 |
165 |
Note
- The number of wires is approximate and wire
diameter is nominal; they shall be such as to satisfy the requirements
of conductor resistance as per Class 5 of IEC 60228 / DIN VDE
0295 / IS 8130 / BS 6360
- In view of continuous improvements
in our design and process, specifications given here in are subject
change without notice.
TPR (Thermoplastic Rrubber cables) 3 CORE
FLAT CABLES

| 3 CORE FLAT CABLES
FOR SUBMERSIBLE PUMPS (1100 VOLTS)
|
| CONDUCTOR |
PVC INSULATION
|
PVC SHEATH |
Conductor Resistance
at 20°C (max) ohms/km |
CURRENT
Rating at 40°C
Amps. |
 |
Nominal
Area in
|
Nos.
& Dia.
of wire
|
Nominal
Thickness |
Nominal
Core Dia. |
Nominal
Thickness
|
Approx.
Overall
Dimensions |
| Sq.
mm. |
Nos.
/ mm |
mm |
mm |
mm |
Thickness
mm |
Width
mm |
| 1.50 |
22/0.30 |
0.80 |
3.25 |
1.15 |
6.00 |
12.80 |
12.10 |
14 |
| 2.50 |
36/0.30 |
0.90 |
3.84 |
1.15 |
6.40 |
14.60 |
7.41 |
18 |
| 4.00 |
56/0.30 |
1.00 |
4.50 |
1.15 |
7.40 |
16.80 |
4.95 |
26 |
| 6.00 |
85/0.30 |
1.00 |
5.30 |
1.15 |
7.90 |
18.70 |
3.30 |
31 |
| 10.00 |
140/0.30 |
1.00 |
6.50 |
1.40 |
9.90 |
23.70 |
1.91 |
42 |
| 16.00 |
226/0.30 |
1.00 |
8.00 |
1.40 |
11.40 |
28.00 |
1.21 |
57 |
| 25.00 |
354/0.30 |
1.20 |
10.10 |
2.00 |
14.70 |
35.50 |
0.780 |
72 |
| 35.00 |
495/0.30 |
1.20 |
11.30 |
2.00 |
16.20 |
39.50 |
0.554 |
90 |
| 50.00 |
703/0.30 |
1.40 |
13.60 |
2.20 |
18.30 |
45.50 |
0.386 |
115 |
| 70.00 |
440/0.45 |
1.40 |
15.30 |
2.20 |
20.00 |
51.00 |
0.272 |
143 |
| 95.00 |
475/0.50 |
1.60 |
18.00 |
2.40 |
23.50 |
60.00 |
0.206 |
165 |
Note
- The number of wires is approximate and wire
diameter is nominal; they shall be such as to satisfy the requirements
of conductor resistance as per Class 5 of IEC 60228 / DIN VDE
0295 / IS 8130 / BS 6360
- In view of continuous improvements
in our design and process, specifications given here in are subject
change without notice.
TPR (Thermoplastic Rrubber cables) 4 CORE
FLAT CABLES

| 4 CORE FLAT CABLES
FOR SUBMERSIBLE PUMPS (1100 VOLTS)
|
| CONDUCTOR
|
TPR
INSULATION |
TPR
SHEATH |
Conductor
Resistance at 20°C (max) ohms/km |
CURRENT
Rating at 40°C
Amps. |
 |
Nominal
Area in
|
Nos.
& Dia.
of wire
|
Nominal
Thickness |
Nominal
Core Dia. |
Nominal
Thickness
|
Approx.
Overall
Dimensions |
| Sq.
mm. |
Nos.
/ mm |
mm |
mm |
mm |
Thickness
mm |
Width
mm |
| 1.50 |
22/0.30 |
0.80 |
3.25 |
1.30 |
6.00 |
15.80 |
12.10 |
14 |
| 2.50 |
36/0.30 |
0.90 |
3.84 |
1.30 |
6.50 |
18.00 |
7.41 |
18 |
| 4.00 |
56/0.30 |
1.00 |
4.50 |
1.45 |
7.60 |
21.00 |
4.95 |
26 |
| 6.00 |
85/0.30 |
1.00 |
5.30 |
1.50 |
7.90 |
24.30 |
3.30 |
31 |
| 10.00 |
140/0.30 |
1.00 |
6.50 |
1.80 |
9.90 |
29.70 |
1.91 |
42 |
| 16.00 |
226/0.30 |
1.00 |
8.00 |
1.95 |
11.80 |
36.00 |
1.21 |
57 |
| 25.00 |
354/0.30 |
1.20 |
10.10 |
2.00 |
14.70 |
45.10 |
0.780 |
72 |
| 35.00 |
495/0.30 |
1.20 |
11.50 |
2.00 |
16.20 |
50.10 |
0.554 |
90 |
| 50.00 |
703/0.30 |
1.40 |
13.60 |
2.20 |
18.30 |
58.10 |
0.386 |
115 |
| 70.00 |
440/0.45 |
1.40 |
15.30 |
2.20 |
20.00 |
66.50 |
0.272 |
143 |
| 95.00 |
475/0.50 |
1.60 |
18.00 |
2.40 |
23.50 |
77.30 |
0.206 |
165 |
Note
- The number of wires is approximate and wire
diameter is nominal; they shall be such as to satisfy the requirements
of conductor resistance as per Class 5 of IEC 60228 / DIN VDE
0295 / IS 8130 / BS 6360
- In view of continuous improvements in our
design and process, specifications given here in are subject change
without notice
TPR (Thermoplastic Rrubber cables) 3 CORE
ROUND CABLES

| 3 CORE ROUND CABLES
FOR SUBMERSIBLE PUMPS (1100 VOLTS)
|
| CONDUCTOR
|
TPR
INSULATION |
TOTAL
THICKNESS OF DOUBLE TPR SHEATH |
Conductor
Resistance at 20°C (max) ohms/km |
CURRENT
Rating at 40°C
Amps. |
 |
Nominal
Area in
|
Nos.
& Dia.
of wire
|
Nominal
Thickness |
Nominal
Core Dia. |
Nominal
Thickness
|
Approx.
Overall
Dimensions |
| Sq.
mm. |
Nos.
/ mm |
mm |
mm |
mm |
mm |
| 1.50 |
22/0.30 |
0.80 |
3.25 |
1.50 |
10.00 |
12.10 |
14 |
| 2.50 |
36/0.30 |
0.90 |
3.84 |
1.50 |
11.00 |
7.41 |
18 |
| 4.00 |
56/0.30 |
1.00 |
4.50 |
1.60 |
13.00 |
4.95 |
26 |
| 6.00 |
85/0.30 |
1.00 |
5.30 |
1.60 |
14.60 |
3.30 |
31 |
| 10.00 |
140/0.30 |
1.00 |
6.50 |
2.00 |
18.00 |
1.91 |
42 |
| 16.00 |
226/0.30 |
1.00 |
8.00 |
2.00 |
21.20 |
1.21 |
57 |
| 25.00 |
354/0.30 |
1.20 |
10.10 |
2.15 |
26.00 |
0.780 |
72 |
| 35.00 |
495/0.30 |
1.20 |
11.30 |
2.15 |
28.30 |
0.554 |
90 |
| 50.00 |
703/0.30 |
1.40 |
13.60 |
2.25 |
33.50 |
0.386 |
115 |
| 70.00 |
440/0.45 |
1.40 |
15.30 |
2.45 |
37.80 |
0.272 |
143 |
| 95.00 |
475/0.50 |
1.60 |
18.00 |
2.40 |
43.50 |
0.206 |
165 |
Note
- The number of wires is approximate and wire
diameter is nominal; they shall be such as to satisfy the requirements
of conductor resistance as per Class 5 of IEC 60228 / DIN VDE
0295 / IS 8130 / BS 6360
- In view of continuous improvements
in our design and process, specifications given here in are subject
change without notice.
TPR (Thermoplastic Rrubber cables) 4 CORE
ROUND CABLES

| 4 CORE ROUND CABLES
FOR SUBMERSIBLE PUMPS (1100 VOLTS)
|
| CONDUCTOR
|
TPR
INSULATION |
TOTAL
THICKNESS OF DOUBLE TPR SHEATH |
Conductor
Resistance at 20°C (max) ohms/km |
CURRENT
Rating at 40°C
Amps. |
 |
Nominal
Area in
|
Nos.
& Dia.
of wire
|
Nominal
Thickness |
Nominal
Core Dia. |
Nominal
Thickness
|
Approx.
Overall
Dimensions |
| Sq.
mm. |
Nos.
/ mm |
mm |
mm |
mm |
mm |
| 1.50 |
22/0.30 |
0.80 |
3.25 |
1.50 |
10.80 |
12.10 |
14 |
| 2.50 |
36/0.30 |
0.90 |
3.84 |
1.65 |
12.50 |
7.41 |
18 |
| 4.00 |
56/0.30 |
1.00 |
4.50 |
1.65 |
14.10 |
4.95 |
26 |
| 6.00 |
85/0.30 |
1.00 |
5.30 |
1.65 |
16.00 |
3.30 |
31 |
| 10.00 |
140/0.30 |
1.00 |
6.50 |
2.00 |
20.35 |
1.91 |
42 |
| 16.00 |
226/0.30 |
1.00 |
8.00 |
2.00 |
23.40 |
1.21 |
57 |
| 25.00 |
354/0.30 |
1.20 |
10.10 |
2.20 |
28.80 |
0.780 |
72 |
| 35.00 |
495/0.30 |
1.20 |
11.50 |
2.20 |
31.50 |
0.554 |
90 |
| 50.00 |
703/0.30 |
1.40 |
13.60 |
2.30 |
37.30 |
0.386 |
115 |
| 70.00 |
440/0.30 |
1.40 |
15.30 |
2.60 |
42.20 |
0.272 |
143 |
| 95.00 |
475/0.50 |
1.60 |
18.00 |
2.65 |
48.80 |
0.206 |
165 |
Note
- The number of wires is approximate and wire
diameter is nominal; they shall be such as to satisfy the requirements
of conductor resistance as per Class 5 of IEC 60228 / DIN VDE
0295 / IS 8130 / BS 6360
- In view of continuous improvements in our
design and process, specifications given here in are subject change
without notice.
|